- Date
- 12/02/2021
- W/O
- 0921912
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00821
- PipeID
- P17094
- Time
- 3:16 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H2032
- Sewer Name
- 22 PUDDINGSTONE TRUNK, SECTS 1&2
- City
- SAN DIMAS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 23
- Purpose
- Capital Improvement Program Assesment
- Project
- 20211202MDM_PUDDINGSTONE_TRUNK_SECTS_1_2
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 22 0738
- Downstream MH
- 22 0737
- Dir. of Survey
- Downstream
- Length Surveyed
- 441.7 ft.
- Total Length
- 441.7 ft.
- Structural Index
- 2
- Structural Quick
- 3122
- Structural Rating
- 7
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 22 0738 to 22 0737 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING FLAKING CONCRETE

2.5 ft. - General Observation - 15% OLD MAG COAT ON PIPE

29.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

354.7 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open