Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2021, 06:20 AM
  • H 0087_H 0086_10142021_224359.mp4

Date
10/14/2021
W/O
916413
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00165
PipeID
P10539
Time
11:20 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9446
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_916413_TV01220_OCT2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Square
Height
36 in.
Width
36 in.
Upstream MH
H 0087
Downstream MH
H 0086
Dir. of Survey
Downstream
Length Surveyed
774.3 ft.
Total Length
774.3 ft.
Structural Index
3
Structural Quick
5]3^
Structural Rating
1530
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
1530
Pipe schematic from manhole H 0087 to H 0086
MH: H 0087MH: H 0086downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 00870 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2.3 ft. MGO - General Observation - MAG COAT2.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start774.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish774.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish774.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish774.3 ft. AMH - Downstream Manhole, Survey Ends - H 0086 - "SIPHON OBSERVED"

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
774.3SAP
774.3SRV
0AMHH 0087
0MWL
2.3MGOMAG COAT
0MWM
774.3SSS
774.3AMHH 0086 - "SIPHON OBSERVED"
2.5SAP
2.5SSS
14.2SRV

Properties (7)

additional_info
630074101421201
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2021-10-14T23:20:23-07:00
documentation
PROPIPE
is_lateral_inspection
false