Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2021, 03:18 PM
  • CAP_29 0461_09282021_084847.mp4

Date
09/28/2021
W/O
916503
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00989
PipeID
P24505
Time
8:18 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9142
Sewer Name
29 LEWIS AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_916503_TV29059_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0461
Downstream MH
CAP
Dir. of Survey
Upstream
Length Surveyed
360.2 ft.
Total Length
360.2 ft.
Structural Index
3
Structural Quick
3421
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 29 0461 to CAP
MH: 29 0461MH: CAPupstream0 ft. AMH - Upstream Manhole, Survey Ends - CAP0.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"3.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"28.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES53.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"55.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"58.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"105.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"107.8 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES - .141.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES152.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"155.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"175.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish206.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"208.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"253.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"256.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"334.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start334.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"336.8 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES - .336.8 ft. FL - Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES337.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"347 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES360.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0461360.2 ft. MWL - Water Level, 5 %of cross sectional area360.2 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (7)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    13.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Repair Localized Liner, within 8 inches of joint: YES - .

    23.4 ft. - Repair Localized Liner, within 8 inches of joint: YES - .

  • Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES

    23.4 ft. - Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    26.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    218.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Repair Localized Liner, within 8 inches of joint: YES - .

    252.4 ft. - Repair Localized Liner, within 8 inches of joint: YES - .

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    331.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (26)

DistanceCodeObservation
254.7TFC
0AMH29 0461
207.4TFC
13.2CL
25.6TF
331.8CM
218.5CM
185.1CM
204.8TFA
357.1TFC
106.3TFA
103.9TFC
151.6TF
26.1CM
0MWL
306.9TFC
154.1TF
360.2AMHCAP
301.7TF
23TF
252.4RPL.
0MWM
359.7TFC
23.4RPL.
304.3TF
23.4FL

Properties (7)

additional_info
630138092821061
custom_field_three
CRACKS, FRACTURES
custom_field_two
3
customer
1
datetime
2021-09-28T08:18:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false