Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 19, 2021, 11:03 AM
  • 14 0950_14 0949_10192021_030651.mp4

Date
10/19/2021
W/O
916874
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00957
PipeID
P23166
Time
4:03 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9467
Sewer Name
14 AVENUE "H" WEST TRUNK
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
05
Purpose
Routine Assessment
Project
WO_916874_TV14044_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
14 0949
Downstream MH
14 0950
Dir. of Survey
Upstream
Length Surveyed
8.2 ft.
Total Length
8.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4200
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 14 0949 to 14 0950
MH: 14 0949MH: 14 0950upstream0 ft. MSA - Survey Abandoned - DUE TO SLUDGE.0 ft. DSZ - Deposits Settled Other, 25 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish6.2 ft. DSZ - Deposits Settled Other, 25 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE8.2 ft. AMH - Downstream Manhole, Survey Begins - 14 09498.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (2)

  • Deposits Settled Other,  25 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start - SLUDGE

    2 ft. - Deposits Settled Other, 25 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

  • Survey Abandoned - DUE TO SLUDGE.

    8.2 ft. - Survey Abandoned - DUE TO SLUDGE.

Observations (5)

DistanceCodeObservation
8.2MSADUE TO SLUDGE.
8.2DSZ
2DSZSLUDGE
0AMH14 0949
0MWM

Properties (7)

additional_info
630069101821201
custom_field_three
ABANDONED DUE TO SLUDGE/DEBRIS
custom_field_two
5
customer
1
datetime
2021-10-19T04:03:50-07:00
documentation
PRO PIPE
is_lateral_inspection
false