Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 18, 2021, 11:03 AM
  • 14 0955_14 0954_10182021_031910.mp4

Date
10/18/2021
W/O
916874
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00957
PipeID
P23171
Time
4:03 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9466
Sewer Name
14 AVENUE "H" WEST TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
05
Purpose
Routine Assessment
Project
WO_916874_TV14044_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
14 0955
Downstream MH
14 0954
Dir. of Survey
Downstream
Length Surveyed
509.3 ft.
Total Length
509.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2R00
O&M Rating
194
Overall Index
2
Overall Quick
Overall Rating
194
Pipe schematic from manhole 14 0955 to 14 0954
MH: 14 0955MH: 14 0954downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 09550 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area21.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start508 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish509.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0954

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    21.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
509.3AMH14 0954
0AMH14 0955
508DAGS
21.6DAGS
0MWL
0MWM

Properties (7)

additional_info
630069101821001
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-10-18T04:03:14-07:00
documentation
PRO PIPE
is_lateral_inspection
false