Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2021, 09:01 AM
  • 14 0963_14 0962_10152021_011338.mp4

Date
10/15/2021
W/O
916874
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00957
PipeID
P23179
Time
2:01 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9465
Sewer Name
14 AVENUE "H" WEST TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
Routine Assessment
Project
WO_916874_TV14044_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
14 0963
Downstream MH
14 0962
Dir. of Survey
Downstream
Length Surveyed
527.5 ft.
Total Length
527.5 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 14 0963 to 14 0962
MH: 14 0963MH: 14 0962downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 09630 ft. MWL - Water Level, 5 %of cross sectional area295.7 ft. CS - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES527.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE527.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK527.5 ft. AMH - Downstream Manhole, Survey Ends - 14 0962

Observation photos (2)

  • Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

    295.7 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    527.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (7)

DistanceCodeObservation
0MWM
527.5MGOCOCKROACHES IN MANHOLE
0AMH14 0963
527.5MGOCONNECTION AT MH 9 O'CLOCK
295.7CS
527.5AMH14 0962
0MWL

Properties (7)

additional_info
630069101421201
custom_field_three
SPIRAL CRACK
custom_field_two
3
customer
1
datetime
2021-10-15T02:01:42-07:00
documentation
PRO PIPE
is_lateral_inspection
false