- Date
- 10/20/2021
- W/O
- 916871
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00570
- PipeID
- P18550
- Time
- 1:28 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9468
- Sewer Name
- 14 AVENUE "I" TRUNK
- City
- LANCASTER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_916871_TV14045_OCT2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 14 0460
- Downstream MH
- 14 0461
- Dir. of Survey
- Upstream
- Length Surveyed
- 224.5 ft.
- Total Length
- 224.5 ft.
- Structural Index
- 3
- Structural Quick
- 3G00
- Structural Rating
- 120
- O&M Index
- 2
- O&M Quick
- 2H00
- O&M Rating
- 86
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 206
Pipe schematic from manhole 14 0460 to 14 0461 Observation photos (3)

0 ft. - General Observation - COCKROACHES IN MANHOLE

8.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

23.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start