Wastewater/Activity/PacpInspection/1.0Oct 14, 2021, 09:01 AM
  • H 0191_H 0190_10142021_023252.mp4

Date
10/14/2021
W/O
916726
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00169
PipeID
P11215
Time
2:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9445
Sewer Name
H JOINT OUTFALL H - UNIT 2C
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
WO_916726_TV02168_OCT2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
H 0191
Downstream MH
H 0190
Dir. of Survey
Downstream
Length Surveyed
428.9 ft.
Total Length
428.9 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
425
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
427
Pipe schematic from manhole H 0191 to H 0190
MH: H 0191MH: H 0190downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 01912.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start159.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"204.8 ft. TFI - Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"332.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"428.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK428.9 ft. AMH - Downstream Manhole, Survey Ends - H 0190428.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish428.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    204.8 ft. - Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

Observations (13)

DistanceCodeObservation
428.9MGOCONNECTION AT THE MH 3 OC'LOCK
204.8TFI
159.5TF
332.9TF
0MWM
428.9AMHH 0190
0MGOCONNECTION AT THE MH 3 OC'LOCK
428.9SSS
0MWL
2.3SSS
0AMHH 0191
2.3SAP
428.9SAP

Properties (7)

additional_info
630074101321202
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-10-14T02:01:17-07:00
documentation
PROPIPE
is_lateral_inspection