Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 27, 2021, 08:18 AM
  • C 0322_C 0321_09272021_012507.mp4

Date
09/27/2021
W/O
911835
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00136
PipeID
P09785
Time
1:18 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9423
Sewer Name
C JOINT OUTFALL C - UNIT 6G
City
ARTESIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
40
Purpose
Routine Assessment
Project
RFIR_WO_911835_TV02311_SEP2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
C 0322
Downstream MH
C 0321
Dir. of Survey
Downstream
Length Surveyed
71.3 ft.
Total Length
71.3 ft.
Structural Index
3
Structural Quick
5B3B
Structural Rating
145
O&M Index
2
O&M Quick
2B00
O&M Rating
26
Overall Index
3
Overall Quick
Overall Rating
171
Pipe schematic from manhole C 0322 to C 0321
MH: C 0322MH: C 0321downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 03220 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 45% MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12 ft. SRV - Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES, Start49.6 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES69 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish69 ft. SRV - Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES, Finish69 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish71.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish71.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish71.3 ft. AMH - Downstream Manhole, Survey Ends - C 0321

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES, Start

    12 ft. - Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    49.6 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
71.2SAV
69SRV
71.3AMHC 0321
2DAGS
49.6SRV
0AMHC 0322
69SRV
2MGO45% MAG COAT
0MWL
2.1SAV
12SRV
69DAGS
0MWM
71.2SSS
2.1SSS

Properties (7)

additional_info
630074092721001
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2021-09-27T01:18:21-07:00
documentation
PROPIPE
is_lateral_inspection
false