Wastewater/Activity/PacpInspection/1.0Sep 27, 2021, 08:39 AM
  • C 0320_C 0319_09272021_015443.mp4

Date
09/27/2021
W/O
911835
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00136
PipeID
P09783
Time
1:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9423
Sewer Name
C JOINT OUTFALL C - UNIT 6G
City
ARTESIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
40
Purpose
Routine Assessment
Project
RFIR_WO_911835_TV02311_SEP2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
C 0320
Downstream MH
C 0319
Dir. of Survey
Downstream
Length Surveyed
265.6 ft.
Total Length
265.6 ft.
Structural Index
3
Structural Quick
5G3J
Structural Rating
473
O&M Index
2
O&M Quick
2I00
O&M Rating
104
Overall Index
3
Overall Quick
Overall Rating
577
Pipe schematic from manhole C 0320 to C 0319
MH: C 0320MH: C 0319downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 03200 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. MGO - General Observation - 70% MAG COAT55 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start218.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - POSSIBLE ABANDONED CONN228 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 4"234.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - POSSIBLE ABANDONED CONN243.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - POSSIBLE ABANDONED CONN262.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES262.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish263 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish263 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish265.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE265.6 ft. AMH - Downstream Manhole, Survey Ends - C 0319265.6 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    55 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    262.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
2.6SAV
265.6MGOCONN @ MH 9 O'CLOCK/ACTIVE
218.3TFCPOSSIBLE ABANDONED CONN
262.3SAP
0AMHC 0320
228TFB
2.6MGO70% MAG COAT
234.8TFCPOSSIBLE ABANDONED CONN
0MWM
262.3SAV
263SSS
2SSS
265.6AMHC 0319
265.6SRV
55SRV
243.2TFCPOSSIBLE ABANDONED CONN
2DAGS
0MWL
263DAGS

Properties (7)

additional_info
630074092721001
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2021-09-27T01:39:43-07:00
documentation
PROPIPE
is_lateral_inspection
false