Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 28, 2021, 05:35 AM
  • C 0653_C 0652_10272021_225731.mp4

Date
10/27/2021
W/O
916510
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00266
PipeID
P23919
Time
10:35 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9266
Sewer Name
C JOINT OUTFALL C - UNIT 3F
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_916510_TV03162_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
C 0653
Downstream MH
C 0652
Dir. of Survey
Downstream
Length Surveyed
311.8 ft.
Total Length
311.8 ft.
Structural Index
3
Structural Quick
423J
Structural Rating
167
O&M Index
2
O&M Quick
2K00
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
291
Pipe schematic from manhole C 0653 to C 0652
MH: C 0653MH: C 0652downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 06532.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start41.2 ft. CM - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES53.3 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES57.4 ft. CM - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES61.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start98.4 ft. FM - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES197.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES311.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish311.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish311.8 ft. AMH - Downstream Manhole, Survey Ends - C 0652

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

    41.2 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    53.3 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    57.4 ft. - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    61.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    98.4 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    197.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
41.2CM
2.5DAGS
197.2FM
311.8AMHC 0652
98.4FM
0MWL
57.4CM
311.4CM
311.4DAGS
53.3CM
61.3CM
0MWM
0AMHC 0653

Properties (8)

additional_info
630074102721201
custom_field_three
CRACKS, FRACTURES
custom_field_two
2
customer
1
datetime
2021-10-27T22:35:41-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
37482