Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2021, 08:26 AM
  • 14 0129_14 0128_10082021_003234.mp4

Date
10/08/2021
W/O
916872
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00571
PipeID
P18159
Time
1:26 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9456
Sewer Name
14 DISTRICT #14 OUTFALL TRUNK
City
LANCASTER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_916872_TV14007_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
14 0128
Downstream MH
14 0129
Dir. of Survey
Upstream
Length Surveyed
137.1 ft.
Total Length
137.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412D
O&M Rating
58
Overall Index
2
Overall Quick
Overall Rating
58
Pipe schematic from manhole 14 0128 to 14 0129
MH: 14 0128MH: 14 0129upstream0 ft. AMH - Upstream Manhole, Survey Ends - 14 01292.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish135.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start137.1 ft. MWM - Water Mark, 50 %of cross sectional area137.1 ft. AMH - Downstream Manhole, Survey Begins - 14 0128137.1 ft. MWL - Water Level, 40 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
2DAGS
0MWM
134.6DAGS
137.1AMH14 0129
0AMH14 0128
0MWL

Properties (7)

additional_info
630069100721201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-10-08T01:26:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false