Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2021, 08:13 AM
  • 14 0127_14 0126_10082021_002210.mp4

Date
10/08/2021
W/O
916872
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00571
PipeID
P18157
Time
1:13 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9456
Sewer Name
14 DISTRICT #14 OUTFALL TRUNK
City
LANCASTER
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_916872_TV14007_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
14 0127
Downstream MH
14 0126
Dir. of Survey
Downstream
Length Surveyed
220.2 ft.
Total Length
220.2 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
129
O&M Index
2
O&M Quick
2H00
O&M Rating
86
Overall Index
3
Overall Quick
Overall Rating
215
Pipe schematic from manhole 14 0127 to 14 0126
MH: 14 0127MH: 14 0126downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 01270 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start3.8 ft. CM - Crack Multiple, from 08 to 09 o'clock, within 8 inches of joint: YES7.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"20 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"30.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"198 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"201.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"218.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE218.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish218.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish220.2 ft. AMH - Downstream Manhole, Survey Ends - 14 0126

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Multiple, from 08 to 09 o'clock, within 8 inches of joint: YES

    3.8 ft. - Crack Multiple, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    218.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
0AMH14 0127
0MGOCOCKROACHES IN MANHOLE
120.9TBA
218.8MGOCOCKROACHES IN MANHOLE
2DAGS
30.9TBA
220.2AMH14 0126
0MWL
7.9CM
198TFC
20TFC
201.1TFC
3.8CM
0MWM
218.8CM
16.5TFC
218.8DAGS

Properties (7)

additional_info
630069100721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-10-08T01:13:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false