Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2021, 07:06 AM
  • 14 0740_14 0739_09222021_231126.mp4

Date
09/23/2021
W/O
916872
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00571
PipeID
P18143
Time
12:06 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9375
Sewer Name
14 DISTRICT #14 OUTFALL TRUNK
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
05
Purpose
Routine Assessment
Project
WO_916872_TV14007_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
14 0740
Downstream MH
14 0739
Dir. of Survey
Downstream
Length Surveyed
104.6 ft.
Total Length
104.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412C
O&M Rating
44
Overall Index
2
Overall Quick
Overall Rating
44
Pipe schematic from manhole 14 0740 to 14 0739
MH: 14 0740MH: 14 0739downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 07400 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start102.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish104.6 ft. AMH - Downstream Manhole, Survey Ends - 14 0739

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0MWL
102.6DAGS
0AMH14 0740
104.6AMH14 0739
0MWM
2DAGS

Properties (7)

additional_info
630069092221202
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-09-23T00:06:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false