Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2021, 07:03 AM
  • 14 0738_14 0737_10072021_230939.mp4

Date
10/08/2021
W/O
916872
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00571
PipeID
P18141
Time
12:03 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9456
Sewer Name
14 DISTRICT #14 OUTFALL TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
05
Purpose
Routine Assessment
Project
WO_916872_TV14007_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
14 0738
Downstream MH
14 0737
Dir. of Survey
Downstream
Length Surveyed
191 ft.
Total Length
191 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2F00
O&M Rating
74
Overall Index
2
Overall Quick
Overall Rating
74
Pipe schematic from manhole 14 0738 to 14 0737
MH: 14 0738MH: 14 0737downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 07380 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start189 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish191 ft. AMH - Downstream Manhole, Survey Ends - 14 0737191 ft. MGO - General Observation - STOP LOG CONNECTION AT MH 9 O'CLOCK

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2DAGS
0AMH14 0738
191AMH14 0737
189DAGS
0MWM
191MGOSTOP LOG CONNECTION AT MH 9 O'CLOCK
0MWL

Properties (7)

additional_info
630069100721201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-10-08T00:03:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false