Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2021, 06:04 AM
  • 02 1823_02 1822_10072021_232102.mp4

Date
10/07/2021
W/O
916506
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00236
PipeID
P04170
Time
11:04 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9437
Sewer Name
02 ATLANTIC AVENUE RELIEF TRUNK
City
E. LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_916506_TV02017_OCT2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 1823
Downstream MH
02 1822
Dir. of Survey
Downstream
Length Surveyed
408.2 ft.
Total Length
408.2 ft.
Structural Index
3
Structural Quick
3O2O
Structural Rating
405
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
405
Pipe schematic from manhole 02 1823 to 02 1822
MH: 02 1823MH: 02 1822downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 18230 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start408.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK408.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1822408.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish408.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMH02 1823
2.3SAP
0MWM
2.3SSS
408.2MGOCONNECTION AT THE MH 9 OC'LOCK
408.2AMH02 1822
0MWL
408.2SAP
408.2SSS

Properties (7)

additional_info
630074100721201
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-10-07T23:04:28-07:00
documentation
PROPIPE
is_lateral_inspection
false