Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2021, 06:21 AM
  • 02 1834_02 1833_10122021_234840.mp4

Date
10/12/2021
W/O
916325
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00240
PipeID
P04184
Time
11:21 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9442
Sewer Name
02 CITY TERRACE DIVERSION EXTENSION TRUNK
City
E.LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_916325_TV02028_OCT2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 1833
Downstream MH
02 1834
Dir. of Survey
Upstream
Length Surveyed
443 ft.
Total Length
443 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
264
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
264
Pipe schematic from manhole 02 1833 to 02 1834
MH: 02 1833MH: 02 1834upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Ends - 02 18340 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish440.5 ft. MGO - General Observation - MAG COAT440.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start443 ft. MWM - Water Mark, 20 %of cross sectional area443 ft. AMH - Downstream Manhole, Survey Begins - 02 1833443 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.5MGOMAG COAT
0MWM
443MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH02 1833
443AMH02 1834
0MWL
2.5SAV
443SAV

Properties (7)

additional_info
630074101221201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
4
customer
1
datetime
2021-10-12T23:21:04-07:00
documentation
PROPIPE
is_lateral_inspection
false