Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2021, 08:39 AM
  • 02 1831_02 1830A_10132021_014442.mp4

Date
10/13/2021
W/O
916325
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00240
PipeID
P04181
Time
1:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9442
Sewer Name
02 CITY TERRACE DIVERSION EXTENSION TRUNK
City
E.LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_916325_TV02028_OCT2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 1830A
Downstream MH
02 1831
Dir. of Survey
Upstream
Length Surveyed
121.9 ft.
Total Length
121.9 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
72
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
72
Pipe schematic from manhole 02 1830A to 02 1831
MH: 02 1830AMH: 02 1831upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 18310 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish119.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start119.5 ft. MGO - General Observation - MAG COAT121.9 ft. MWM - Water Mark, 20 %of cross sectional area121.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK121.9 ft. AMH - Downstream Manhole, Survey Begins - 02 1830A121.9 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK
2.4SAV
121.9AMH02 1831
0AMH02 1830A
0MWL
121.9SAV
2.4MGOMAG COAT

Properties (7)

additional_info
630074101221201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
4
customer
1
datetime
2021-10-13T01:39:05-07:00
documentation
PROPIPE
is_lateral_inspection
false