Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2021, 06:24 PM
  • 15 0849_15 0848_1182021_110042.mp4

Date
11/08/2021
W/O
0921847
Weather
Dry
Operator/Surveyor
SHADLER
Sewer ID
Z00594
PipeID
P12627
Time
10:24 AM
Certificate
U-415-06024035
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H2008
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20211108KS_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.399999618530273 in.
Upstream MH
15 0849
Downstream MH
15 0848
Dir. of Survey
Downstream
Length Surveyed
203.1 ft.
Total Length
203.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 15 0849 to 15 0848
MH: 15 0849MH: 15 0848downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION @ U/S MH 9 O'CLK. UNKNOWN STATUS0 ft. AMH - Upstream Manhole, Survey Begins - 10:50 A.M.23.8 ft. MGO - General Observation - LINER SHOWS WRINKLING - 12 TO 4 O'CLK.146 ft. RFB - Roots Fine Barrell, from 12 to 04 o'clock, within 8 inches of joint: YES - 25% OF CROSS-SECTION149.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - 100 % OF CONNECTION CROSS-SECTION158.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 4" - 50% ROOTS CROSS-SECTION203.1 ft. AMH - Downstream Manhole, Survey Ends - 11:33 A.M. / DROP MH

Observation photos (2)

  • Roots Fine Barrell, from 12 to 04 o'clock, within 8 inches of joint: YES - 25% OF CROSS-SECTION

    146 ft. - Roots Fine Barrell, from 12 to 04 o'clock, within 8 inches of joint: YES - 25% OF CROSS-SECTION

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - 100 % OF CONNECTION CROSS-SECTION

    149.1 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - 100 % OF CONNECTION CROSS-SECTION

Observations (8)

DistanceCodeObservation
0MWL
23.8MGOLINER SHOWS WRINKLING - 12 TO 4 O'CLK.
0MGOCONNECTION @ U/S MH 9 O'CLK. UNKNOWN STATUS
0AMH10:50 A.M.
158.8TFD50% ROOTS CROSS-SECTION
203.1AMH11:33 A.M. / DROP MH
146RFB25% OF CROSS-SECTION
149.1TF100 % OF CONNECTION CROSS-SECTION

Properties (9)

additional_info
POST ROOT EVALUATION
custom_field_three
LINER
custom_field_two
4
customer
LACSD
datetime
2021-11-08T10:24:02-08:00
documentation
SHADLER, IGNACIO, BRAR
is_lateral_inspection
false
lining
CIPP
year_laid
20020918