Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2021, 09:13 AM
  • 02 1171_02 1170_07142021_022643.mp4

Date
07/14/2021
W/O
901517
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00350
PipeID
P04565
Time
2:13 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9076
Sewer Name
02 GARFIELD AVENUE TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_901517_TV02336_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1171
Downstream MH
02 1170
Dir. of Survey
Downstream
Length Surveyed
299.7 ft.
Total Length
299.7 ft.
Structural Index
3
Structural Quick
514K
Structural Rating
638
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
3
Overall Quick
Overall Rating
756
Pipe schematic from manhole 02 1171 to 02 1170
MH: 02 1171MH: 02 1170downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11710 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 7 O'CLOCK/UNKNOWN0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6 ft. B - Broken, from 03 to 04 o'clock, within 8 inches of joint: YES6.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"27 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES62 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start67.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"117.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"168 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"218.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"266.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN291.1 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES297 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish297 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish297 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish297 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish299 ft. MGO - General Observation - ROACHES @ MH299.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1170

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
2SSS
0MWL
16.8TFC
297CM
297MWLS
2DAGS
6.2FM
299MGOROACHES @ MH
168TFC
297SSS
297DAGS
2CM
27FM
299.7FM
6B
291.1B
117.7TFC
0AMH02 1171
67.2TFC
62MWLS
299.7AMH02 1170
0MGOROACHES @ MH
218.8TFC
0MGOCONN @ MH 7 O'CLOCK/UNKNOWN
266.9TFOPEN
0MWM

Properties (7)

additional_info
630074071321204
custom_field_three
BROKEN PIPE/MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-07-14T02:13:26-07:00
documentation
PROPIPE
is_lateral_inspection
false