Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2021, 09:47 AM
  • 14 0209_14 0208_09012021_030519.mp4

Date
09/01/2021
W/O
911937
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00584
PipeID
P18248
Time
2:47 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9345
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_911937_TV14035_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
14 0209
Downstream MH
14 0208
Dir. of Survey
Downstream
Length Surveyed
232.2 ft.
Total Length
232.2 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
2
O&M Quick
2H00
O&M Rating
92
Overall Index
3
Overall Quick
Overall Rating
230
Pipe schematic from manhole 14 0209 to 14 0208
MH: 14 0209MH: 14 0208downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 02090 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start71.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN78.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN128.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN130.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN188.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN191.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN230.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish230.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.2 ft. AMH - Downstream Manhole, Survey Ends - 14 0208

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
130.9TFOPEN
2DAGS
0MWL
0AMH14 0209
230.2DAGS
2CM
188.9TFOPEN
230.2CM
232.2AMH14 0208
78.1TFOPEN
71.6TFOPEN
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
128.4TFOPEN
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
191.4TFOPEN

Properties (7)

additional_info
630069083121202
custom_field_three
MULTIPLE CRACKS/SPALLING
custom_field_two
3
customer
1
datetime
2021-09-01T02:47:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false