- Date
- 10/21/2021
- W/O
- 0921554
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00032
- PipeID
- P11335
- Time
- 4:48 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1982
- Sewer Name
- E JOINT OUTFALL E - UNIT 5
- City
- WILLBROOK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 13
- Purpose
- Capital Improvement Program Assesment
- Project
- 202121MDM_JOINT_OUTFALL_E_UNIT_5
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- E 0108
- Downstream MH
- E 0109
- Dir. of Survey
- Upstream
- Length Surveyed
- 18.6 ft.
- Total Length
- 18.6 ft.
- Structural Index
- 4
- Structural Quick
- 5141
- Structural Rating
- 14
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole E 0108 to E 0109 Observation photos (7)

2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - BLISTERING PEELING CONCRETE

2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG VERY SPORATIC

8 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG

18 ft. - General Photograph - CORRODED CIRCUM REBAR

18 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

18 ft. - General Observation - CORRISON BEYOUND REBAR

18.6 ft. - Survey Abandoned - UPLEG DOWNSTREAM SIPHON