Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 24, 2021, 05:34 AM
  • 02 1851_02 1850_09232021_225252.mp4

Date
09/23/2021
W/O
911343
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00255
PipeID
P04210
Time
10:34 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9421
Sewer Name
02 DOWNEY-BELLFLOWER RELIEF TRUNK, SECTION 2
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_911343_TV02394_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
12 in.
Upstream MH
02 1851
Downstream MH
02 1850
Dir. of Survey
Downstream
Length Surveyed
497.7 ft.
Total Length
497.7 ft.
Structural Index
4
Structural Quick
4C31
Structural Rating
77
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
77
Pipe schematic from manhole 02 1851 to 02 1850
MH: 02 1851MH: 02 1850downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 185136.1 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES395.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES401.8 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES410.1 ft. FM - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES416.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES422.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start497.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1850497.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    36.1 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    395.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    401.8 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    410.1 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    416.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    422.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
497.7AMH02 1850
497.7FM
0MWM
0MWL
0MGOCONNECTION AT THE MH 9 OC'LOCK
410.1FM
0AMH02 1851
422.2FM
401.8FM
395.8CL
416.3FM
36.1FL

Properties (7)

additional_info
630074092321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-09-23T22:34:11-07:00
documentation
PROPIPE
is_lateral_inspection
false