Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2021, 09:55 AM
  • 16 0092_16 0091_09152021_031509.mp4

Date
09/15/2021
W/O
911589
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00639
PipeID
P13106
Time
2:55 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9408
Sewer Name
16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_911589_TV16084_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
16 0092
Downstream MH
16 0091
Dir. of Survey
Downstream
Length Surveyed
457.3 ft.
Total Length
457.3 ft.
Structural Index
3
Structural Quick
433Q
Structural Rating
284
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
284
Pipe schematic from manhole 16 0092 to 16 0091
MH: 16 0092MH: 16 0091downstream0 ft. AMH - Upstream Manhole, Survey Begins - 16 00920 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK8.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start74.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"90.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES270.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES273.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES275.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"288.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"375.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"388.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"406.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"427.4 ft. FM - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES428.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"457.3 ft. AMH - Downstream Manhole, Survey Ends - 16 0091457.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED457.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (15)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    74.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    90.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    175.2 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    188.8 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    245.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES

    270.9 ft. - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    273.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    275.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    288.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    375.6 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    388.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    406.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

    427.4 ft. - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    428.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (23)

DistanceCodeObservation
275.5TB
273.4FM
90.5TB
188.8TB
388.1TB
0AMH16 0092
457.3AMH16 0091
457.3MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
0MGOCONNECTION AT THE MH 3 OC'LOCK
245.7FM
0MWL
74.4TB
0MWM
457.3CM
175.2TB
8.6CM
288.3TB
270.9FC
406.4TB
428.8TB
375.6TB
0MGOCONNECTION AT THE MH 9 OC'LOCK
427.4FM

Properties (7)

additional_info
630074091421202
custom_field_three
FRACTURES, CRACKS
custom_field_two
2
customer
1
datetime
2021-09-15T02:55:33-07:00
documentation
PROPIPE
is_lateral_inspection
false