- Date
- 09/01/2021
- W/O
- 911334
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00521
- PipeID
- P05939
- Time
- 12:27 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9343
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
- City
- INGLEWOOD
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_911334_TV05308_SEP2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 10 in.
- Upstream MH
- 05 0716
- Downstream MH
- 05 0715
- Dir. of Survey
- Downstream
- Length Surveyed
- 363.1 ft.
- Total Length
- 363.1 ft.
- Structural Index
- 4
- Structural Quick
- 4M21
- Structural Rating
- 278
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 278
Pipe schematic from manhole 05 0716 to 05 0715 Observation photos (2)

8.6 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

18.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start