Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 24, 2021, 06:22 AM
  • 08 0300_08 0299_09232021_233613.mp4

Date
09/23/2021
W/O
911332
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00012
PipeID
P00345
Time
11:22 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9377
Sewer Name
08 JAMES STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
WO_911332_TV08023_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
12 in.
Upstream MH
08 0300
Downstream MH
08 0299
Dir. of Survey
Downstream
Length Surveyed
272.1 ft.
Total Length
272.1 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
159
O&M Index
2
O&M Quick
2B00
O&M Rating
30
Overall Index
3
Overall Quick
Overall Rating
189
Pipe schematic from manhole 08 0300 to 08 0299
MH: 08 0300MH: 08 0299downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 03000 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 10 %of cross sectional area3.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start76.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.3 ft. MGO - General Observation - PIPE (VCP) APPEARS "PITTED" / ROUGH THROUGHOUT LINE.177.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 03 o'clock, , within 8 inches of joint: YES, Start269.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish269.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 03 o'clock, , within 8 inches of joint: YES, Finish272.1 ft. AMH - Downstream Manhole, Survey Ends - 08 0299272.1 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 03 o'clock,  , within 8 inches of joint: YES, Start

    194.4 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 03 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
177.5TFC
0MWL
269.7CM
269.7DAGS
0AMH08 0300
3.8CM
0MGOCOCKROACHES IN MANHOLE
109.3MGOPIPE (VCP) APPEARS "PITTED" / ROUGH THROUGHOUT LINE.
272.1AMH08 0299
194.4DAGS
0MWM
272.1MGOACTIVE CONNECTION AT MH 9 O'CLOCK
76.1TFC

Properties (7)

additional_info
630069092321201
custom_field_three
CRACKS
custom_field_two
2
customer
1
datetime
2021-09-23T23:22:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false