Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2021, 07:29 AM
  • 15 0397_15 0396_10152021_004914.mp4

Date
10/15/2021
W/O
091798
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00597
PipeID
P12320
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1974
Sewer Name
15 ARROYO DRIVE TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
31
Purpose
Routine Assessment
Project
20211013MDM_ARROYO_DRIVE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
15 0397
Downstream MH
15 0396
Dir. of Survey
Downstream
Length Surveyed
119.2 ft.
Total Length
119.2 ft.
Structural Index
2
Structural Quick
4132
Structural Rating
32
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 15 0397 to 15 0396
MH: 15 0397MH: 15 0396downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 12:40AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE6.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT9.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL9.8 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL12.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL14.8 ft. MGO - General Observation - LINK PIPE START17.8 ft. MGO - General Observation - LINK PIPE FINISH20.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped25.7 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL26.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped28.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL28.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL31.1 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL51.9 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H73.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped74.5 ft. MGO - General Observation - LINK PIPE START 2 LINK PIPES79.4 ft. MGO - General Observation - LINK PIPE FINISH107.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL107.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL111 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL114.3 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL119.2 ft. AMH - Downstream Manhole, Survey Ends - 1:05AM

Observation photos (3)

  • General Observation - LINK PIPE START

    14.8 ft. - General Observation - LINK PIPE START

  • General Observation - LINK PIPE START 2 LINK PIPES

    74.5 ft. - General Observation - LINK PIPE START 2 LINK PIPES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    111 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (26)

DistanceCodeObservation
14.8MGOLINK PIPE START
12.8FCSL
74.5MGOLINK PIPE START 2 LINK PIPES
0MGOConn. @ Mh, 3 O' Clock. Active
17.8MGOLINK PIPE FINISH
119.2AMH1:05AM
114.3FCSL
107.6FCSL
9.8FCSL
9.8FCSL
20.5TFCCapped
111FMSL
0AMH12:40AM
73.1TFCCapped
25.7FCSL
3.5FLHAIRLINE
107.6FCSL
0MWL
28.6FCSL
26.4TFCCapped
6.8FLSLIGHT
51.9FCH
0MWM
79.4MGOLINK PIPE FINISH
31.1FCSL
28.6FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2021-10-15T00:29:09-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false