Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2021, 08:15 AM
  • 15 0396_15 0395_10152021_011711.mp4

Date
10/15/2021
W/O
091798
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00597
PipeID
P12319
Time
1:15 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1974
Sewer Name
15 ARROYO DRIVE TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
31
Purpose
Routine Assessment
Project
20211013MDM_ARROYO_DRIVE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
15 0396
Downstream MH
15 0395
Dir. of Survey
Downstream
Length Surveyed
126.3 ft.
Total Length
126.3 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
27
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
27
Pipe schematic from manhole 15 0396 to 15 0395
MH: 15 0396MH: 15 0395downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM12.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE21.3 ft. MGO - General Observation - LINK PIPE START24.4 ft. MGO - General Observation - LINK PIPE FINISH34.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H34.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H39.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped41 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, - SL44.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL58.2 ft. FC - Fracture Circumferential, from 11 to 04 o'clock, within 8 inches of joint: YES - SL64.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H72.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped77.2 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H80.9 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL85.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped96.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL110.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL121.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped126.3 ft. AMH - Downstream Manhole, Survey Ends - 1:40AM

Observation photos (2)

  • General Observation - LINK PIPE START

    21.3 ft. - General Observation - LINK PIPE START

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    44.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (21)

DistanceCodeObservation
96.8FLSL
41FCSL
44.6FMSL
64.7FCH
85.2TFCCapped
34.9FCH
39.6TFCCapped
34.9FCH
72.3TFCCapped
0MWL
21.3MGOLINK PIPE START
126.3AMH1:40AM
24.4MGOLINK PIPE FINISH
0MWM
58.2FCSL
110.4FLSL
77.2FCH
121.7TFCCapped
12.4FLHAIRLINE
0AMH1:15AM
80.9FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2021-10-15T01:15:25-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection