Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 14, 2021, 10:19 AM
  • 15 0397_15 0396_10142021_033202.mp4

Date
10/14/2021
W/O
091798
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00597
PipeID
P12320
Time
3:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1973
Sewer Name
15 ARROYO DRIVE TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
31
Purpose
Routine Assessment
Project
20211013MDM_ARROYO_DRIVE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
15 0396
Downstream MH
15 0397
Dir. of Survey
Upstream
Length Surveyed
44.2 ft.
Total Length
44.2 ft.
Structural Index
3
Structural Quick
4231
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 15 0396 to 15 0397
MH: 15 0396MH: 15 0397upstream0 ft. MSA - Survey Abandoned - LINK PIPE4.6 ft. MGO - General Observation - LINK PIPE6.4 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - SLIGHT33.2 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SL37.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT41.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT44.2 ft. AMH - Downstream Manhole, Survey Begins - 3:35AM44.2 ft. MWM - Water Mark, 20 %of cross sectional area44.2 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (9)

DistanceCodeObservation
39.6MGOLINK PIPE
37.8FLSLIGHT
3FMSLIGHT
7FMSLIGHT
11FCSL
0AMH3:35AM
0MWM
44.2MSALINK PIPE
0MWL

Properties (4)

customer
LACSD
datetime
2021-10-14T03:19:57-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection