Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 3, 2021, 09:11 AM
  • 05 1100_05 1099_09032021_022038.mp4

Date
09/03/2021
W/O
911335
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00488
PipeID
P06334
Time
2:11 AM
Certificate
U-508-7069`
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9349
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
WO_911335_TV05306_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
05 1100
Downstream MH
05 1099
Dir. of Survey
Downstream
Length Surveyed
191.4 ft.
Total Length
191.4 ft.
Structural Index
3
Structural Quick
3D11
Structural Rating
70
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
70
Pipe schematic from manhole 05 1100 to 05 1099
MH: 05 1100MH: 05 1099downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 11000 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 25 %of cross sectional area3.1 ft. CC - Crack Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES25.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - TAP CAP (NOT "WHOLE") DAMAGED & AN APPARENT "GAP" - (2 PIECES?) PRESENT.63.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES83.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start122.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURED TAP CAP191.4 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 3 OC'LOCK191.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1099191.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES

    3.1 ft. - Crack Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    63.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    83.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0AMH05 1100
0MWL
191.4MGOACTIVE CONNECTION AT THE MH 3 OC'LOCK
0MGOACTIVE CONNECTION AT THE MH 3 OC'LOCK
191.4AMH05 1099
191.4CM
122.8TFCFRACTURED TAP CAP
3.1CC
0MWM
63.2CM
25.5TFCTAP CAP (NOT "WHOLE") DAMAGED & AN APPARENT "GAP" - (2 PIECES?) PRESENT.
83.1CM

Properties (7)

additional_info
630074090221202
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-09-03T02:11:43-07:00
documentation
PROPIPE
is_lateral_inspection
false