- Date
- 09/16/2021
- W/O
- 911345
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00639
- PipeID
- P13075
- Time
- 10:43 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9411
- Sewer Name
- 16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
- City
- SAN MARINO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 18
- Purpose
- Routine Assessment
- Project
- RFIR_WO_911345_TV16004_SEP2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 16 0061
- Downstream MH
- 16 0040
- Dir. of Survey
- Downstream
- Length Surveyed
- 212.3 ft.
- Total Length
- 212.3 ft.
- Structural Index
- 3
- Structural Quick
- 413G
- Structural Rating
- 214
- O&M Index
- 2
- O&M Quick
- 2G00
- O&M Rating
- 84
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 298
Pipe schematic from manhole 16 0061 to 16 0040 Observation photos (5)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

51.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

60.4 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"

90.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES