- Date
- 09/14/2021
- W/O
- 911529
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00775
- PipeID
- P26769
- Time
- 10:44 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9363
- Sewer Name
- 21 LA VERNE-"B" STREET TRUNK
- City
- LA VERNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 05
- Purpose
- Routine Assessment
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 21 0882
- Downstream MH
- 21 0881A
- Dir. of Survey
- Downstream
- Length Surveyed
- 132.1 ft.
- Total Length
- 132.1 ft.
- Structural Index
- 3
- Structural Quick
- 413E
- Structural Rating
- 142
- O&M Index
- 2
- O&M Quick
- 412D
- O&M Rating
- 52
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 194
Pipe schematic from manhole 21 0882 to 21 0881A Observation photos (6)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

7.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

54.6 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

74.8 ft. - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

95.4 ft. - Crack Longitudinal Hinge, 2, from 08 to 10 o'clock, within 8 inches of joint: YES