- Date
- 09/14/2021
- W/O
- 911529
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00775
- PipeID
- P15969
- Time
- 11:02 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9363
- Sewer Name
- 21 LA VERNE-"B" STREET TRUNK
- City
- LA VERNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- RFIR_WO_911529_TV21054_SEP2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 21 0881
- Downstream MH
- 21 0880
- Dir. of Survey
- Downstream
- Length Surveyed
- 247.7 ft.
- Total Length
- 247.7 ft.
- Structural Index
- 2
- Structural Quick
- 3I2J
- Structural Rating
- 253
- O&M Index
- 2
- O&M Quick
- 2I00
- O&M Rating
- 98
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 351
Pipe schematic from manhole 21 0881 to 21 0880 Observation photos (4)

0 ft. - Upstream Manhole, Survey Begins - 21 0881, ABANDONED MH

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

26.3 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES