Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 22, 2021, 08:12 AM
  • 32 0144_32 0143_09222021_012913.mp4

Date
09/22/2021
W/O
911391
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19892
Time
1:12 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9373
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_911391_TV32048_SEP2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0144
Downstream MH
32 0143
Dir. of Survey
Downstream
Length Surveyed
532.3 ft.
Total Length
532.3 ft.
Structural Index
3
Structural Quick
3T00
Structural Rating
318
O&M Index
2
O&M Quick
412T
O&M Rating
216
Overall Index
3
Overall Quick
Overall Rating
534
Pipe schematic from manhole 32 0144 to 32 0143
MH: 32 0144MH: 32 0143downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 01440 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start530.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish530.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish532.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE532.3 ft. AMH - Downstream Manhole, Survey Ends - 32 0143532.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    532.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
0MWL
0AMH32 0144
532.3MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE
532.3AMH32 0143
2SAP
530.8DAGS
530.8SAP
532.3MGOCONNECTION AT MH 9 O'CLOCK
2DAGS
0MWM

Properties (7)

additional_info
630069092121201
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2021-09-22T01:12:20-07:00
documentation
PRO PIPE
is_lateral_inspection
false