Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2021, 04:38 AM
  • 08 0326_08 0325_09072021_214958.mp4

Date
09/07/2021
W/O
911693
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00374
Time
9:38 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9350
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_911693_TV08155_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0326
Downstream MH
08 0325
Dir. of Survey
Downstream
Length Surveyed
340.8 ft.
Total Length
340.8 ft.
Structural Index
4
Structural Quick
4M31
Structural Rating
275
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
275
Pipe schematic from manhole 08 0326 to 08 0325
MH: 08 0326MH: 08 0325downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 03263 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47 ft. H - Hole, at 03 o'clock, within 8 inches of joint: YES - EXSISTING HOLE47.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"101.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"153.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"201.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"253.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"300.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"340.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish340.8 ft. AMH - Downstream Manhole, Survey Ends - 08 0325340.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole, at 03 o'clock, within 8 inches of joint: YES - EXSISTING HOLE

    47 ft. - Hole, at 03 o'clock, within 8 inches of joint: YES - EXSISTING HOLE

Observations (14)

DistanceCodeObservation
47.7TFC
0MWM
340.8AMH08 0325
47HEXSISTING HOLE
201.3TFC
3FM
0MWL
300.9TF
101.7TFC
253.3TFC
340.7FM
153.8TFC
340.8MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH08 0326

Properties (7)

additional_info
630074090721201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-09-07T21:38:22-07:00
documentation
PROPIPE
is_lateral_inspection
false