Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2021, 07:39 AM
  • 08 0318_08 0317_09082021_004959.mp4

Date
09/08/2021
W/O
911693
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00365
Time
12:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9350
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_911693_TV08155_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0318
Downstream MH
08 0317
Dir. of Survey
Downstream
Length Surveyed
328.9 ft.
Total Length
328.9 ft.
Structural Index
4
Structural Quick
4L21
Structural Rating
258
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
258
Pipe schematic from manhole 08 0318 to 08 0317
MH: 08 0318MH: 08 0317downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 03180 ft. MWL - Water Level, 10 %of cross sectional area0.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK4.2 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES8.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start33.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"82.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"133.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"184.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"234.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"328.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK328.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0317

Observation photos (2)

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    4.2 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
8.1FM
234.9TF
328.9MGOCONNECTION AT THE MH 9 OC'LOCK
4.2CL
33.2TF
328.9FM
0MWM
0AMH08 0318
184.3TFC
328.9AMH08 0317
133.3TFC
0MWL
82.8TF
0.7MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074090721201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-09-08T00:39:11-07:00
documentation
PROPIPE
is_lateral_inspection
false