- Date
- 09/08/2021
- W/O
- 911693
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00013
- PipeID
- P00363
- Time
- 1:14 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9350
- Sewer Name
- 08 KEYSTONE TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_911693_TV08155_SEP2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 08 0316
- Downstream MH
- 08 0315
- Dir. of Survey
- Downstream
- Length Surveyed
- 247.6 ft.
- Total Length
- 247.6 ft.
- Structural Index
- 4
- Structural Quick
- 4I00
- Structural Rating
- 196
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 198
Pipe schematic from manhole 08 0316 to 08 0315 Observation photos (2)

2.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

145.9 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"