Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2021, 10:09 AM
  • 08 0306_08 0305A_09132021_031828.mp4

Date
09/13/2021
W/O
911693
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00355
Time
3:09 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9403
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_911693_TV08155_SEP2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
12 in.
Upstream MH
08 0306
Downstream MH
08 0305A
Dir. of Survey
Downstream
Length Surveyed
93 ft.
Total Length
93 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
54
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
54
Pipe schematic from manhole 08 0306 to 08 0305A
MH: 08 0306MH: 08 0305Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 03060 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK4.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start50.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"93 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK93 ft. AMH - Downstream Manhole, Survey Ends - 08 0305A93 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MWL
50.4TFC
0AMH08 0306
4.6CM
93MGOCONNECTION AT THE MH 3 OC'LOCK
93AMH08 0305A
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK
93CM

Properties (7)

additional_info
630074091321002
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-09-13T03:09:57-07:00
documentation
PROPIPE
is_lateral_inspection