Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2021, 06:30 AM
  • 02 1916_02 1346B_08302021_234637.mp4

Date
08/30/2021
W/O
911863
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P04620
Time
11:30 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9340
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
05
Purpose
Routine Assessment
Project
WO_911863_TV02024_SEP2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
02 1916
Downstream MH
02 1346B
Dir. of Survey
Downstream
Length Surveyed
108.7 ft.
Total Length
108.7 ft.
Structural Index
2
Structural Quick
3C2C
Structural Rating
107
O&M Index
2
O&M Quick
2C00
O&M Rating
42
Overall Index
2
Overall Quick
Overall Rating
149
Pipe schematic from manhole 02 1916 to 02 1346B
MH: 02 1916MH: 02 1346Bdownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 19162 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.8 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES88 ft. MWL - Water Level, 10 %of cross sectional area88 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"106 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish106 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish106 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish108.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1346b108.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/OPEN

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    5.8 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
108.7AMH02 1346b
108.7MGOCONN @ MH 9 O'CLOCK/OPEN
5.8CL
0MWM
2CM
0MWL
106DAGS
2DAGS
106CM
106SSS
88MWL
88TFC
0AMH02 1916
2SSS

Properties (7)

additional_info
630074083021201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-08-30T23:30:41-07:00
documentation
PROPIPE
is_lateral_inspection
false