- Date
- 08/30/2021
- W/O
- 911863
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00238
- PipeID
- P03863
- Time
- 4:12 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9339
- Sewer Name
- 02 BELVEDERE TRUNK
- City
- EAST LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_911863_TV02024_SEP2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 27 in.
- Upstream MH
- 02 1338
- Downstream MH
- 02 1339
- Dir. of Survey
- Upstream
- Length Surveyed
- 313.9 ft.
- Total Length
- 313.9 ft.
- Structural Index
- 3
- Structural Quick
- 413X
- Structural Rating
- 500
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 124
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 624
Pipe schematic from manhole 02 1338 to 02 1339 Observation photos (3)

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

116.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

268.5 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"