- Date
- 09/02/2021
- W/O
- 911654
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00110
- PipeID
- P09396
- Time
- 3:15 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9118
- Sewer Name
- B JOINT OUTFALL B - UNIT 8G
- City
- DUARTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_911654_TV15057_SEP2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 42 in.
- Upstream MH
- B 0721
- Downstream MH
- 22 1131
- Dir. of Survey
- Downstream
- Length Surveyed
- 262.9 ft.
- Total Length
- 262.9 ft.
- Structural Index
- 3
- Structural Quick
- 3I2I
- Structural Rating
- 260
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 262
Pipe schematic from manhole B 0721 to 22 1131 Observation photos (4)

2.8 ft. - General Observation - MAG COATING THROUGHOUT

2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

256.6 ft. - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES