- Date
- 09/01/2021
- W/O
- 911654
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00110
- PipeID
- P09386
- Time
- 10:09 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9118
- Sewer Name
- B JOINT OUTFALL B - UNIT 8G
- City
- DUARTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_911654_TV15057_SEP2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 39 in.
- Upstream MH
- B 0713
- Downstream MH
- B 0712
- Dir. of Survey
- Downstream
- Length Surveyed
- 342 ft.
- Total Length
- 342 ft.
- Structural Index
- 3
- Structural Quick
- 3J00
- Structural Rating
- 159
- O&M Index
- 2
- O&M Quick
- 2400
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 167
Pipe schematic from manhole B 0713 to B 0712 Observation photos (4)

2 ft. - General Observation - MAG COATING THROUGHOUT

77.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

180.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

208.3 ft. - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start