Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 4, 2021, 07:30 AM
  • 02 1866_02 1554_1042021_004715.mp4

  • 02 1866_02 1554_1042021_012002.mp4

Date
10/04/2021
W/O
0916642
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00246
PipeID
P04652
Time
12:30 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1958
Sewer Name
02 DOUGLAS AVENUE TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Capital Improvement Program Assesment
Project
20210928MDM_DOUGLAS_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
02 1866
Downstream MH
02 1554
Dir. of Survey
Downstream
Length Surveyed
134.9 ft.
Total Length
134.9 ft.
Structural Index
3
Structural Quick
5148
Structural Rating
108
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
110
Pipe schematic from manhole 02 1866 to 02 1554
MH: 02 1866MH: 02 1554downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:35AM0.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, - HAIRLINE9.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SLIGHT17.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H22.3 ft. FC - Fracture Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES - H27.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - H29.9 ft. FC - Fracture Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES - SL29.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL29.9 ft. MMC - Material Change, Concrete pipe (non-reinfored) - START30.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG31.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FAKING PEELING CONCRETE34.5 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG34.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE35.4 ft. MMC - Material Change, Concrete pipe (non-reinfored) - FINISH35.5 ft. HSV - Hole Soil Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - 1" X1"35.5 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - SL43.4 ft. JOM - Joint Offset Medium - SEALED52.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING OUTER SURFACE62.9 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H65.8 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL67.9 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL70.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT WITH SPALLING74.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped75.5 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL75.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H76.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped78.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H83.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES83.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL85.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H88.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL93.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H101.1 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H101.1 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL106.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL108.6 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL113.5 ft. FC - Fracture Circumferential, from 11 to 04 o'clock, within 8 inches of joint: YES - SL113.5 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H116.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL121 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL122.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped125 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-HOLE UP INSIDE CONN SOIL VISIBLE129.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL129.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, - SL129.1 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H130.8 ft. FC - Fracture Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES - H130.8 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL131.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL133.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL134.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - FLAKING OUTER SURFACE134.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active INCOMING LINE134.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active LARGE OUTGOING134.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - FLAKING OUTER SURFACE134.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT134.9 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (13)

  • Material Change, Concrete pipe (non-reinfored) - START

    29.9 ft. - Material Change, Concrete pipe (non-reinfored) - START

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    30.6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FAKING PEELING CONCRETE

    31.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FAKING PEELING CONCRETE

  • Material Change, Concrete pipe (non-reinfored) - FINISH

    35.4 ft. - Material Change, Concrete pipe (non-reinfored) - FINISH

  • Hole Soil Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - 1" X1"

    35.5 ft. - Hole Soil Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - 1" X1"

  • Joint Offset Medium - SEALED

    43.4 ft. - Joint Offset Medium - SEALED

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING OUTER SURFACE

    52.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING OUTER SURFACE

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL

    67.9 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT WITH SPALLING

    70.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT WITH SPALLING

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

    116.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-HOLE UP INSIDE CONN  SOIL VISIBLE

    125 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-HOLE UP INSIDE CONN SOIL VISIBLE

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES,  - SL

    129.1 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, - SL

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    131.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (58)

DistanceCodeObservation
70.7FMSLIGHT WITH SPALLING
30.6SAMSEVERE AGG
62.9FCH
52.6SSSFLAKING OUTER SURFACE
129.1FCSL
125TFDOPEN-HOLE UP INSIDE CONN SOIL VISIBLE
3FCHAIRLINE
133.1FLSL
0.2FLH
129.1FLSL
74.3TFCCapped
108.6FCSL
65.8FCSL
31.5SSSFAKING PEELING CONCRETE
88.2FCSL
101.1FCH
130.8FCH
83.6FC
131.5FMSL
29.9FCSL
67.9FMSL
101.1FCSL
130.8FCSL
0MWL
113.5FCSL
43.4JOMSEALED
93.5FCH
129.1FCH
134.4FMFLAKING OUTER SURFACE
134.4MGOConn. @ Mh, 9 O' Clock. Active INCOMING LINE
34.5SAMSEVERE AGG
22.3FCH
116.1FLSL
134.4MGOConn. @ Mh, 3 O' Clock. Active LARGE OUTGOING
35.4MMCFINISH
134.4FMFLAKING OUTER SURFACE
75.5FCSL
27.4FMH
0MWM
76.6TFCCapped
122.5TFCCapped
35.5HSV1" X1"
35.5FCSL
121FCSL
85.9FLH
17.2FCH
134.4FMSLIGHT
29.9FLSL
78.6FCH
83.6FMSL
34.5SSSBLISTERING PEELING CONCRETE
0AMH12:35AM
9.6FCSLIGHT
106.1FCSL
113.5FCH
75.5FLH
134.9AMH1:35AM
29.9MMCSTART

Properties (6)

custom_field_three
HOLE SOIL VISIBLE 1" X1"-SLIGHT FRACTURE LONGER
custom_field_two
1
customer
LACSD
datetime
2021-10-04T00:30:39-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLOO
is_lateral_inspection
false