Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 1, 2021, 07:35 AM
  • 22 1125A_22 1125_1012021_005633.mp4

Date
10/01/2021
W/O
0919192
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00820
PipeID
P17507
Time
12:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Heavy Cleaning
Media Label
H1962
Sewer Name
22 POLYMER PLANT WASTE WATER DISPOSAL LINE
City
AZUSA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
04
Purpose
Routine Assessment
Project
20211001MDM_POLYMER_PLANT_WASTE_WATER_DISPOSAL_LINE
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
22 1125A
Downstream MH
22 1125
Dir. of Survey
Downstream
Length Surveyed
342.9 ft.
Total Length
342.9 ft.
Structural Index
3
Structural Quick
5333
Structural Rating
40
O&M Index
3
O&M Quick
4221
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
51
Pipe schematic from manhole 22 1125A to 22 1125
MH: 22 1125AMH: 22 1125downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:45AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active3.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES25.6 ft. MWL - Water Level, 5 %of cross sectional area25.6 ft. MWM - Water Mark, 20 %of cross sectional area53.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT FLAKING OUTER SURFACE74.3 ft. MGO - General Observation - DROP IN ELAVATION99.8 ft. MWL - Water Level, 30 %of cross sectional area99.8 ft. MWM - Water Mark, 60 %of cross sectional area115.3 ft. MGO - General Observation - SLIGHT OFFSET JOINTS IN TURN SEALED156.9 ft. MWL - Water Level, 60 %of cross sectional area173.5 ft. MGP - General Photograph - BROKEN PIPE173.5 ft. BSV - Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET AND OFFSET CIRCUM FRACTURE173.5 ft. BSV - Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET OFFSET FRACTURE173.5 ft. MGO - General Observation - SOIL VISIBLE MODERATE CIRCUM FEACTURE173.5 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT173.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SLIGHT174.5 ft. MGO - General Observation - POSSIBLE VOID BEHIND MODERATE CIRCUM FRACTURE175.4 ft. MLC - Lining Change, - PIPE NOW HAS A LINER176.2 ft. MWM - Water Mark, 20 %of cross sectional area176.2 ft. MWL - Water Level, 5 %of cross sectional area185.7 ft. MLC - Lining Change, Other (enter details in Field 39) - END OF LINER213.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT213.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - HAIRLINE229.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H307.1 ft. B - Broken, from 08 to 12 o'clock, within 8 inches of joint: YES - INSET AND OFFSET SLIGHT CIRCUM FRACTURE307.1 ft. FC - Fracture Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES - SLIGHT308.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SIGHT FRACTURE AND CHIP OUT OF PIPE309 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT309 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE309 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: NO - SLIGHT317.9 ft. RFJ - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YESR - 1%342.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT SPORATIC FLAKING342.9 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (14)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT FLAKING OUTER SURFACE

    53.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT FLAKING OUTER SURFACE

  • General Observation - DROP IN ELAVATION

    74.3 ft. - General Observation - DROP IN ELAVATION

  • General Observation - SLIGHT OFFSET JOINTS IN TURN SEALED

    115.3 ft. - General Observation - SLIGHT OFFSET JOINTS IN TURN SEALED

  • General Photograph - BROKEN PIPE

    173.5 ft. - General Photograph - BROKEN PIPE

  • Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET AND OFFSET CIRCUM FRACTURE

    173.5 ft. - Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET AND OFFSET CIRCUM FRACTURE

  • Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET OFFSET FRACTURE

    173.5 ft. - Broken Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE INSET OFFSET FRACTURE

  • General Observation - SOIL VISIBLE MODERATE CIRCUM FEACTURE

    173.5 ft. - General Observation - SOIL VISIBLE MODERATE CIRCUM FEACTURE

  • General Observation - POSSIBLE VOID BEHIND MODERATE CIRCUM FRACTURE

    174.5 ft. - General Observation - POSSIBLE VOID BEHIND MODERATE CIRCUM FRACTURE

  • Lining Change, - PIPE NOW HAS A LINER

    175.4 ft. - Lining Change, - PIPE NOW HAS A LINER

  • Lining Change, Other (enter details in Field 39) - END OF LINER

    185.7 ft. - Lining Change, Other (enter details in Field 39) - END OF LINER

  • Broken, from 08 to 12 o'clock, within 8 inches of joint: YES - INSET AND OFFSET SLIGHT CIRCUM FRACTURE

    307.1 ft. - Broken, from 08 to 12 o'clock, within 8 inches of joint: YES - INSET AND OFFSET SLIGHT CIRCUM FRACTURE

  • Fracture Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES - SLIGHT

    307.1 ft. - Fracture Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SIGHT FRACTURE AND CHIP OUT OF PIPE

    308.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SIGHT FRACTURE AND CHIP OUT OF PIPE

  • Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: NO - SLIGHT

    309 ft. - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: NO - SLIGHT

Observations (36)

DistanceCodeObservation
173.5MGPBROKEN PIPE
173.5BSVMODERATE INSET AND OFFSET CIRCUM FRACTURE
317.9RFJ1%
3.5DAGS
173.5BSVMODERATE INSET OFFSET FRACTURE
309FCSLIGHT
0MWM
307.1BINSET AND OFFSET SLIGHT CIRCUM FRACTURE
0MWL
115.3MGOSLIGHT OFFSET JOINTS IN TURN SEALED
53.1SSSSLIGHT FLAKING OUTER SURFACE
342.9AMH1:45AM
174.5MGOPOSSIBLE VOID BEHIND MODERATE CIRCUM FRACTURE
185.7MLCEND OF LINER
99.8MWL
74.3MGODROP IN ELAVATION
176.2MWM
213.7FCSLIGHT
25.6MWL
308.4FLSIGHT FRACTURE AND CHIP OUT OF PIPE
173.5MGOSOIL VISIBLE MODERATE CIRCUM FEACTURE
0AMH12:45AM
309FCHAIRLINE
173.5FCSLIGHT
342.5SSSSLIGHT SPORATIC FLAKING
309FCSLIGHT
229.1FCH
99.8MWM
175.4MLCPIPE NOW HAS A LINER
25.6MWM
213.7FLHAIRLINE
0MGOConn. @ Mh, 9 O' Clock. Active
176.2MWL
307.1FCSLIGHT
156.9MWL
173.5FLSLIGHT

Properties (7)

custom_field_three
BROKEN PIPE SOIL VISIBLE
custom_field_two
1
customer
LACSD
datetime
2021-10-01T00:35:23-07:00
documentation
MARTIN,REBELES,OLIVER 111,CASTILLO
is_lateral_inspection
false
year_laid
19740514