Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2021, 07:59 AM
  • 01 0230_01 0229_09102021_011327.mp4

Date
09/10/2021
W/O
911861
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00202
PipeID
P01272
Time
12:59 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9127
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_911861_TV01011_SEP2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
15 in.
Upstream MH
01 0230
Downstream MH
01 0229
Dir. of Survey
Downstream
Length Surveyed
210.5 ft.
Total Length
210.5 ft.
Structural Index
3
Structural Quick
3G21
Structural Rating
125
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
125
Pipe schematic from manhole 01 0230 to 01 0229
MH: 01 0230MH: 01 0229downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02300 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 40 %of cross sectional area2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES59.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"67.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"103 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"105.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"115.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"138.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"148.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"201.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"207.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish210.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0229

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    7.8 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
59.6TF
103TF
148.6TF
115.5TFA
0MWL
7.8CL
0AMH01 0230
0MGOCONNECTION AT THE MH 3 OC'LOCK
207.8SAP
105.5TF
201.8TF
2.2SAP
210.5AMH01 0229
138.5TF
67.5TF
0MWM

Properties (6)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2021-09-10T00:59:02-07:00
documentation
PROPIPE
is_lateral_inspection
false