Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 3, 2021, 06:09 AM
  • 01 0219_01 0218_09022021_233011.mp4

Date
09/02/2021
W/O
911861
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01261
Time
11:09 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9348
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_911861_TV01011_SEP2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
01 0219
Downstream MH
01 0218
Dir. of Survey
Downstream
Length Surveyed
300.7 ft.
Total Length
300.7 ft.
Structural Index
3
Structural Quick
443K
Structural Rating
196
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
196
Pipe schematic from manhole 01 0219 to 01 0218
MH: 01 0219MH: 01 0218downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02190 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 20 %of cross sectional area2.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start57.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"97.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"102.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"109.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"160.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"186 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"186 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES211.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"216.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"247.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"250.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.9 ft. FM - Fracture Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES259.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES300.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK300.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0218

Observation photos (5)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    186 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

    252.9 ft. - Fracture Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    294.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
0AMH01 0219
186TF
0MWL
216.2TF
57.6TF
0MGOCONNECTION AT THE MH 9 OC'LOCK
270.2TF
0MWM
252.9FM
2.9FM
259.7TF
250.2TF
294.9FM
300.7MGOCONNECTION AT THE MH 9 OC'LOCK
102.5TF
300.7SAV
63.7TF
2.9SAV
109.1TF
160.1TF
211.9TF
97.7TF
300.7AMH01 0218
186FM
247.1TF

Properties (7)

additional_info
630074090221201
custom_field_three
AGGREGATE VISIBLE/FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-09-02T23:09:08-07:00