Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2021, 07:44 AM
  • 01 0209_01 0208_09132021_010558.mp4

Date
09/13/2021
W/O
911861
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01251
Time
12:44 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9402
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_911861_TV01011_SEP2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0209
Downstream MH
01 0208
Dir. of Survey
Downstream
Length Surveyed
201.8 ft.
Total Length
201.8 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 01 0209 to 01 0208
MH: 01 0209MH: 01 0208downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 02090 ft. MWL - Water Level, 20 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES29.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"69 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"114.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"119.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"158.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"172.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES197.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES201.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0208201.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    12.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    172.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    197.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
142.6TF
168.5TF
172.5CL
197.8FM
69TF
29.9TF
12.3CL
2.1SAV
0MWM
0MGOCONNECTION AT THE MH 9 OC'LOCK
158.4TF
0AMH01 0209
201.8AMH01 0208
119.8TF
114.5TF
201.8SAV
0MWL

Properties (7)

additional_info
630074091321001
custom_field_three
AGGREGATE VISIBLE/FRACTURES
custom_field_two
3
customer
1
datetime
2021-09-13T00:44:16-07:00
documentation
PROPIPE
is_lateral_inspection
false