- Date
- 08/31/2021
- W/O
- 911390
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z01179
- PipeID
- P26059
- Time
- 1:18 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9250
- Sewer Name
- 14 WEST SIDE RELIEF TRUNK
- City
- LANCASTER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_911390_TV14056_SEP2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Square
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 14 1107
- Downstream MH
- 14 1106
- Dir. of Survey
- Downstream
- Length Surveyed
- 256.4 ft.
- Total Length
- 256.4 ft.
- Structural Index
- 2
- Structural Quick
- 2I00
- Structural Rating
- 100
- O&M Index
- 2
- O&M Quick
- 2S00
- O&M Rating
- 200
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 300
Pipe schematic from manhole 14 1107 to 14 1106 Observation photos (2)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start