- Date
- 09/13/2021
- W/O
- 911293
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00798
- PipeID
- P17242
- Time
- 3:31 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9359
- Sewer Name
- 22 CONEY TRUNK, SECTION 1
- City
- AZUSA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_911293_TV22132_SEP2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0882
- Downstream MH
- 22 0873
- Dir. of Survey
- Upstream
- Length Surveyed
- 14.6 ft.
- Total Length
- 14.6 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole 22 0882 to 22 0873 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

7.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

7.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

14.6 ft. - General Observation - COCKROACHES IN MANHOLE