Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 23, 2021, 09:18 AM
  • H 0241_H 0240_08232021_022815.mp4

Date
08/23/2021
W/O
906511
Weather
Dry
Operator/Surveyor
S, LOPEZ
Sewer ID
Z00171
PipeID
P10660
Time
2:18 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9242
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_906511_TV02170_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 0241
Downstream MH
H 0240
Dir. of Survey
Downstream
Length Surveyed
34 ft.
Total Length
34 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4136
O&M Rating
22
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole H 0241 to H 0240
MH: H 0241MH: H 0240downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 02410 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start34 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish34 ft. MSA - Survey Abandoned - DUE TO GREASE.

Observation photos (2)

  • Deposits Attached Grease, 20 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - DUE TO GREASE.

    34 ft. - Survey Abandoned - DUE TO GREASE.

Observations (6)

DistanceCodeObservation
0MWM
0AMHH 0241
2DAGS
0MWL
34DAGS
34MSADUE TO GREASE.

Properties (7)

additional_info
630069082321001
custom_field_three
ABANDONED DUE TO GREASE
custom_field_two
5
customer
1
datetime
2021-08-23T02:18:21-07:00
documentation
PRO PIPE
is_lateral_inspection
false